Skip to content
Snippets Groups Projects
Commit b99152d4 authored by Alexander Stein's avatar Alexander Stein Committed by Guenter Roeck
Browse files

hwmon: (pwm-fan) Switch regulator dynamically


This adds the enable attribute which is used to select if zero PWM duty
means to switch off regulator and PWM or to keep them enabled but
at inactive PWM output level.
Depending on the select enable mode, turn off the regulator and PWM if
the PWM duty is zero, or keep them enabled.
This is especially important for fan using inverted PWM signal polarity.
Having regulator supplied and PWM disabled, some PWM controllers provide
the active, rather than inactive signal.

With this change the shutdown as well as suspend/resume paths require
modifcations as well.

Signed-off-by: default avatarAlexander Stein <alexander.stein@ew.tq-group.com>
Link: https://lore.kernel.org/r/20220914153137.613982-6-alexander.stein@ew.tq-group.com


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 9db6e7f5
No related branches found
No related tags found
Loading
Loading
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment