ALSA: usb - Avoid unnecessary sample rate changes on USB 2.0 clock sources


The Scarlett 2i2 seems to take almost 500 ms to set the sample rate,
even if the clock is currently set to that value. This patch speeds
up prepare of the device, by avoiding setting the clock to something
it already is.

Signed-off-by: default avatarDavid Henningsson <david.henningsson@canonical.com>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
parent 4b417cf0
No related branches found
No related tags found
No related merge requests found
......@@ -356,6 +356,8 @@ static int set_sample_rate_v2(struct snd_usb_audio *chip, int iface,
return clock;
prev_rate = get_sample_rate_v2(chip, iface, fmt->altsetting, clock);
if (prev_rate == rate)
return 0;
cs_desc = snd_usb_find_clock_source(chip->ctrl_intf, clock);
writeable = uac2_control_is_writeable(cs_desc->bmControls, UAC2_CS_CONTROL_SAM_FREQ - 1);
......